SECTION 08 31
16
(1995 - 08310)
PART 1: GENERAL
1.01 WORK
INCLUDED
A. Metal Access Panels
B. Options and Accessories
1.02 RELATED
WORK
A. Section 08 31 16-Floor Doors
B. Section 08 31 16-Sidewalk Doors
1.03
REFERENCES
A. NFPA8O-Fire Doors
B. Fire-rated access panels tested and
certified by Underwriters Laboratories (UL), and labeled with 1-1/2 hour "B"
fire rating far wall applications.
C. Fire-rated access panels tested and
certified by Warnock Hersey International (WH I), and labeled with 3 hour rating
for non-combustible and 1 hour rating for combustible floor/ceiling assemblies.
1.04 QUALITY
ASSURANCE
A. Fire Resistance Ratings
1. Whenever a fire-rated access panel is
indicated, provide complete access panel assembly with door, frame, hinge and
latch as tested and labeled by U.L. and/or W.H.I.
B. Size Variations
1 Obtain Architects acceptance of
manufacturer’s standard size units which may vary slightly from sizes indicated.
C. Coordination
1. Furnish inserts and anchoring devices
which must be built into other work for installation of access doors.
2. Coordinate delivery with other work to
avoid delay.
PART 2:
PRODUCTS
2.01 ACCEPTABLE
MANUFACTURERS
A. Units listed as follows are provided by
JL. Industries, Inc., 4450 West 78th StreetCircle, Bloomington, MN 55435, (952)
835-6850. Fax: (952) 835-2218
2.02 FIRE RATED ACCESS
PANELS
A. Where indicated on drawings, provide
J.L.’s FD Series, model number _______,with door dimensions of ________
x________Access panel to be equipped with universal (turn ring or keylock) latch
mechanism.
2.03 NON-RATED ACCESS
PANELS
A. Where indicated on drawings, provide
J.L.s Series with door dimensions of x________ Access panel to be equipped with
screwdriver-operated cam latch.
2.04 OPTIONS AND ACCESSORIES
A. Mortise Prep option for FD Series
B. Cylinder lock option for non-rated
access panels.
PART 3: EXECUTION
3.01
INSPECTION
A. Verify that openings are correctly
dimensioned to receive doors.
3.02
INSTALLATION
A. Install per manufacturer’s
recommendations.
3.03 ADJUST AND
CLEAN
A. Adjust latching (locking) mechanism to
operate smoothly.
B. Leave work area clean and free of
debris.
C. Remove and replace panels or frames
which are bowed, warped or damaged
|